OPERATION11. SETTING AND DISPLAYING DATA
B–63614EN/01
632
Displays the current position of the tool in a relative coordinate system
based on the coordinates set by the operator. The current position changes
as the tool moves. The increment system is used as the unit for numeric
values. The title at the top of the screen indicates that relative coordinates
are used.
Display procedure for the current position screen with the relative coordinate system
1 Press function key
POS
.
2 Press soft key
[REL].
MEM STRT MTN *** 09:06:35
[ ABS ] [ REL ] [ ALL ] [ HNDL ] [ OPRT ]
ACTUAL POSITION(RELATIVE) O1000 N00010
PART COUNT 5
RUN TIME 0H15M CYCLE TIME 0H 0M38S
ACT.F 3000 MM/M S 0 T0000
X 123.456
Y 363.233
Z 0.000
See Explanations for the procedure for setting the coordinates.
The current position of the tool in the relative coordinate system can be
reset to 0 or preset to a specified value as follows:
Procedure to set the axis coordinate to a specified value
1 Enter an axis address (such as X or Y) on the screen for the relative
coordinates. The indication for the specified axis blinks and the soft
keys change as shown on the left.
2 ⋅ To reset the coordinate to 0, press soft key
[ORGIN]. The relative
coordinate for the blinking axis is reset to 0.
⋅ To preset the coordinate to a specified value, enter the value and
press soft key
[PRESET]. The relative coordinate for the blinking
axis is set to the entered value.
11.1.2
Position Display in the
Relative Coordinate
System
Explanations
D Resetting the relative
coordinates
Procedure
ORIGIN
246.912
Y 913.780
Z 578.246
>X
MEM
PRESET
X