5. CONNECTION TO CNC PERIPHERALS
B–63003EN/04
96
1 RXD
2 *RXD
3 TXD
4 *TXD
11 0V
12 0V
13
(RXTM1)
14
(RXTM2)
5
(RXALM)
6
(*RXALM)
7
(TXALM)
8
(*TXALM)
15
(TXTM1)
16
(TXTM2)
17
(COMMA)
18
(*COMMA)
9
(ATCH1)
10
19
20
(ATCH2)
Power Mate, i series CNC
JD41 [JD45]
(PCR–EV20MDT)
JD41
(PCR–EV20MDT)
Cable wiring (J45)
Recommended wire material specifications:
A66L–0001–0284#10P (#28AWG10 pair)
1
2
1
2
RXD
RXD
3
4
3
4
11
12
11
12
Shield
*RXD
TXD
*TXD
0V
0V
*RXD
TXD
*TXD
0V
0V
1 RXD
2 *RXD
3 TXD
4 *TXD
11 0V
12 0V
13
(RXTM1)
14
(RXTM2)
5
(RXALM)
6
(*RXALM)
7
(TXALM)
8
(*TXALM)
15
(TXTM1)
16
(TXTM2)
17
(COMMA)
18
(*COMMA)
9
(ATCH1)
10
19
20
(ATCH2)
J45
JD41
JD41B
Recommended connector:
PCR–E20FS or PCR–E20FA
Housing PCR–V20LA
CRT link adapter
NOTE
Connector names in brackets [ ] are for when an i series
CNC is used.
NOTE
1 Place the CRT link adapter right next to (within 500 mm) the
Power Mate to keep the cable between the Power Mate and
the CRT link adapter as short as possible.
2 The cable between the CRT/MDI unit (JD13) and the CRT
link adapter (JD41B) is the same as the above.
3 The cable between the CRT link adapter (JD41A) and the
CRT link adapter (JD41B) is the same as the above.
4 Signals in parentheses () are used on a separate interface.
Take care not to connect to these signals.