B. 20–PIN INTERFACE CONNECTORS AND CABLES
B–63003EN/04
478
Table B.5 Recommended connectors, applicable housings, and cables
Connector name
referenced in the
Connection
Manual
FANUC–approved
connector
(manufacturer)
FANUC–approved
housing
(manufacturer)
Compatible cable (cable diameter)
FANUC development
FANUC specification number
Remark
PCR–E20FA
Strand
PCR–E20FA
(Honda Tsushin)
PCR–V20LA
(Honda Tsushin)
A66L–0001–0284#10P
(6.2 mm in diameter)
Plastic housing
press–mount type
FI30–20S
(Hirose Electric)
FI–20–CV2
(Hirose Electric)
A66L–0001–0284#10P
(6.2 mm in diameter)
Plastic housing
FCN–247J020–G/E
(Fujitsu Takamizawa)
FCN–240C020–Y/S
(Fujitsu Takamizawa)
A66L–0001–0284#10P
(6.2 mm in diameter)
Plastic housing
52622–2011
(Molex)
52624–2015
(Molex)
Plastic housing
PCR–E20FA
Strand wire
press–mount type
FI30–20S
(Hirose Electric)
FI–20–CV7
(Hirose Electric)
Plastic housing
PCR–E20FS
Soldering type
PCR–E20FS
(Honda Tsushin)
PCR–V20LA
(Honda Tsushin)
Plastic housing
FI40–20S
(Hirose Electric)
FI–20–CV2
(Hirose Electric)
Plastic housing
FI40B–2015S
(formerly
FI40–2015S)
15–pin soldering
FI40B–2015S
(formerly
FI40–2015S)
(Hirose Electric)
FI–20–CV5
(Hirose Electric)
A66L–0001–0367
A66L–0001–0368
(9.2 mm in diameter)
Plastic housing
type
FI40B–20S
(Hirose Electric)
FI–20–CV6
(Hirose Electric)
A66L–0001–0403 (*1)
(9.8 mm in diameter)
Metal housing
NOTE
*1 Cable A66L–0001–0286 has been recommended for use as a pulse coder cable. It can be
up to 20 m long. Two cables, A66L–0001–0402 and A66L–0001–0403, have recently been
developed. A66L–0001–0402 and A66L–0001–0403 can be as long as 30 m and 50 m,
respectively. (See Fig. 4 for detailed specifications.)
Both cables have the same level of oil and bending resistance (cable, 100 mm in diameter,
capable of withstanding at least 10 million bending cycles) as conventional cables, and are
UL– and CSA–certified.
B.5
RECOMMENDED
CONNECTORS,
APPLICABLE
HOUSINGS, AND
CABLES