6. SPINDLE CONNECTION
B–63003EN/04
140
1
2
3
4
15
17
19
10
9
18
20
12
14
16
SOUTA
*SOUTA
SINA
*SINA
SOUTB
*SOUTB
SINB
*SINB
+5V
+5V
+5V
0V
0V
0V
SINA
*SINA
SOUTA
*SOUTA
SINB
*SINB
SOUTB
*SOUTB
+5V
+5V
+5V
0V
0V
0V
Ground plate
Shield
JA41
Cable connection
JA48
3
4
1
2
15
17
19
10
9
18
20
12
14
16
Recommended cable connector:
PCR–E20FA (manufactured by Honda Tsushin Kogyo)
FI30–20S (manufactured by Hirose Electric)
FCN–247J020–G/E (manufactured by Fujitsu)
52622–2011 (manufactured by Molex Japan)
Recommended cable specification: A02B–0236–K847
Recommended wire specification: A66L–0001–0284#10P
(#28AWG × 10 pairs)
NOTE
1 When this cable is installed close to other cables such as a
power line, a shielded wire needs to be connected to the
ground plate. When the CNC is installed close to the serial
spindle connector panel, however, a connection to the
ground plate is unnecessary.
2 The recommended cable connector FI30–20S
(manufactured by Hirose Electric) cannot be used for the
stand–alone type i Series CNC and JA48.