B–63003EN/04
10. CONNECTION TO FANUC I/O Link
361
Ambient temperature Operation: 0°C to 58°C
Storage and transportation: –20°C to 60°C
Temperature change 1.1°C/minute maximum
Humidity Normal condition: 75% (relative humidity)
Short term (no more than one month): 95% (relative
humidity)
Vibration Operation: 0.5 G or less
Atmosphere Normal machining factory environment (For use in an
environment with relatively high levels of dust, coolant,
organic solutions, and so forth, special consideration is
required.)
Name Ordering code Remarks
Distribution
A02B–0236–C141#TBS Small, used for T, symbol key sheet
I/O machine
operator’s
A02B–0236–C141#TBR Small, used for T, English key sheet
panel
A02B–0236–C141#MBS Small, used for M, symbol key sheet
A02B–0236–C141#MBR Small, used for M, English key sheet
Distribution
I/O machine
A02B–0236–C140#TBS Standard–size, used for T,
symbol key sheet
operator’s
panel
A02B–0236–C140#TBR Standard–size, used for T,
English key sheet
A02B–0236–C140#MBS Standard–size, used for M,
symbol key sheet
A02B–0236–C140#MBR Standard–size, used for M,
English key shee
Fuse
(accessory)
A03B–0815–K001 1A
10.12.13
Specifications
Setting environment