B–63323EN/03
7. CONNECTION TO CNC PERIPHERALS
267
CP1A
CP1A
0V
+24V
3
2
1
COP20B
+24V
0V
COP20A
CP1B (NOTE1)
0V
+24V
3
2
1
+24V
0V
1
2
Control unit
Optical fiber cable (NOTE2)
LCD unit
Control unit (CP5) or
external power supply
24VDC constant power
supply (24VDC "10%)
AMP Japan
1–178288–3 (housing)
1–175218–5 (contact)
AMP Japan
2–178288–3 (housing)
1–175218–5 (contact)
Be sure to connect protective ground.
Cable connection
D Power cable
Recommended cable length (including external power source): A02B–0124–K830
(length: 5m, with M3 terminal on 24V power source side)
Recommended cable specification (Control unit (CP5)–LCD unit (CP1)): A02B–0261–K801
(Length: 5m)
NOTE
1. The 24 VDC input to CP1A can be taken from
CP1B for branching.
CP1A and CP1B are directly connected to
gether inside the unit.
2. The optical fiber cable can be extended using
a optical fiber relay unit. For details, see the
corresponding appendix.
D Optical fiber cable
For details on optical fiber cable, see the Appendix.
7.1.1.1
Conection of LCD unit
(for 1LCD connection)