8. HIGH–SPEED SERIAL BUS (HSSB)
B–63323EN/03
330
With the rotary switch SW1 on the board and the jumper plug SW5 on the
intelligent terminal or PANEL i, the start sequence at power–up can be
changed.
Setting of
rotary switch
SW1
Jumper
plug
(SW5)
Description
0 Open Setting for maintenance.
The start menu appears, allowing you to perform
boot and IPL operations from the intelligent ter-
minal and PANEL i.
1 Open Normal setting.
The start menu is not displayed.
You cannot perform boot and IPL operations
from the intelligent terminal and PANEL i.
2 Con-
nected
The CNC and the intelligent terminal or PANEL i
start separately without handshaking.
S CNC
– Even when the intelligent terminal or PAN-
EL i is not connected to the CNC or is off,
just the CNC can be started and operated.
(For CNC operation, a CNC–dedicated dis-
play, an MDI unit, an operator’s panel, and
so on are required.)
– Even when the intelligent terminal or PAN-
EL i is connected and is on, the start menu
is not displayed.
S Intelligent terminal or PANEL i
– Even when the CNC is not connected or is
off, just the intelligent terminal or PANEL i
can be started and operated.
– The temperature management function of
the intelligent terminal or PANEL i does not
work. Before using the intelligent terminal
or PANEL i, check that its temperature is
within the recommended temperature
range.
– Even when the CNC is connected to the
intelligent terminal or PANEL i is on, the
start menu is not displayed. You cannot
perform boot and IPL operations from the
intelligent terminal or PANEL i.
For normal operation, this setting is prohibited.
Use this setting only for maintenance.
NOTE
1 For the jumper plug (SW5) position on the intelligent
terminal, see Section 9.7. For the jumper plug (SW5)
position on the PANEL i, see Section 10.7.
2 Do not turn the power to the CNC on and off while the power
to the intelligent terminal is kept on.
3 The intelligent terminal for the PCI bus has been renamed
the FANUC PANEL i.
D Setting/adjustment
location: Rotary switch
SW1 (when an intelligent
terminal or PANEL i is
connected)