B–63323EN/03
9. FANUC INTELLIGENT TERMINAL
345
The spaces described below are required around the intelligent terminal.
A: This space is required to lead in cables. According to the cables used,
secure an appropriate space in portion A shown in the figure below.
If performing ISA expansion, determine the length of X by
considering the cables used with the ISA expansion boards to be
installed.
B: This space is required if the battery is to be replaced without removing
the intelligent terminal from the panel. In addition, the operator must
be capable of working from the rear of the intelligent terminal.
C: This space is required to improve the air flow.
D To replace the fuse without removing the intelligent terminal from the
panel, the operator must be capable of working from the rear of the
terminal. (No special space is required.)
Rear
B
Front
C
C
A
B
ISA expansion
Fuse
Battery
A
X
110
290
50
80
(In mm)
9.6
INSTALLATION
SPACES
10.4” LCD type