9. FANUC INTELLIGENT TERMINAL
B–63323EN/03
342
The cabinet in which the intelligent terminal is to be installed must satisfy
the installation environment conditions described below.
Ambient
temperature
Operating : 5 to 45°C (*1)
Non–operating : –20 to 60°C
Temperature
changes
0.3 °C/min max.
Ambient relative
humidity
Usually: 10 to 75% (no condensation)
10 to 90% for a short period (one month or shorter) (no
condensation)
Wet–bulb temperature: 29 °C or lower
Vibration Operating: 0.5G or less (*2)
Non–operating: 1.0G or less
Atmosphere Install the intelligent terminal in a fully sealed cabinet.
Height Operating: –60 to 1000 m
Non–operating: –60 to 12000 m
*1 Operating ambient temperature
The temperature sensor located in the intelligent terminal monitors
the temperature to determine whether it is in the above range. (The
state can be checked with the LED on the high–speed serial bus
interface board on the CNC.)
(1) If the temperature is outside the permissible temperature range
when the power is turned on, the system stops with nothing
displayed on the screen. The error state can be checked on the
above LED display.
If the temperature falls within the range later, the system,
including the intelligent terminal, is automatically started up.
(2) If the temperature gets out of the range after startup, an error
occurs when an attempt is made to access the hard disk.
*2 Vibration:
The intelligent terminal or its built–in hard disk may resonate at an
indefinite frequency.
After installing the intelligent terminal in the machine, perform a
thorough check.
If an ISA expansion board is used, the permissible amount of
vibration may be lower than that given above, depending on the
specifications of the board.
9.5
SPECIFICATIONS
9.5.1
Installation
Environment
Conditions