8. EDITING MACHINING PROGRAMS
B–62444E–1/04
OPERATION
102
Changing chamfering (C2) to rounding (R3)
PROC (01) AREA HEAD ROUGHNES TOOL–NO CUT–SPD FEED/REV T–CODE
BAR (R) OUTER END HEAD–L 5 102 80 0.25 0101
START X= 20.000 Z= 0.000
² X= 20.000 Z= 30.000
¾ X= 77.172 Z= 58.58
JCHAMFRX= 84.000 Z= 60.000
° X= 10.000 Z= 60.000
< WINDOW
OFF
INSERT ALTER MCHN–C TOOL–D PLOTALTER
FIGURE
DELETE DETAIL
DATA
BEVEL AMOUNT I= 2.000
ROUGHNESS(1–10) SR= 5
CONTR FORM(CHAMFER)
SR=5
Move the cursor (J) to the chamfering data to be changed, then
[ALTER FIGURE]
Check that the graphic pattern menu is displayed on the soft key field, then
[ROUND]
Check that the input data items for rounding are displayed in the window
guidance, move the cursor to the radius of rounding, then
3
INPUT
[ALTER FIGURE]
By performing the operation above, the contour is recomputed and the
changed figure data is displayed on the screen. The new figure is
displayed on the same screen.
Example