Default File List for CAP
System
variables
Standard-
value
Contents, Default display
#6135 54
Additional work coordinate system (not available)
#6136
Specification of peck cycle (ZH06)
#6137
0
not used,
selected
automatically
by
Parameter
5101
Specification of shift direction (ZH04, ZH05)
see also Paramter 5101 #5 #4 (Q in G76/G87)
0 0 = X+
0 1 = X-
1 0 = Y+
1 1 = Y-
#6138 1
Specification of of finishing (ZH03)
#6139 0
Specification of start angle (ZI09)
#6140 2
Specification of Offset data (ZI06)
#6141 1
Mirror type ’Copy’
#6142 1
Pre set ’Corner Rounding’
#6143 1
Pre set ’Start Point 1’
#6144 1
ZH01 G81 for Pre Tools
#6145 4
ZH02 G81 for Pre Tools
#6146 2
ZH03 G81 for Pre Tools
#6147 2
ZH03 G81 for Pre Tools, Bore rough
#6148 6
ZH03 G81 for Pre Tools, Bore finish
#6149 3
ZH04 G81 for Pre Tools
#6150 2
ZH04 G81 for Pre Tools
#6151 2
ZH05 G81 for Pre Tools
#6152 2
ZH06 G81 for Pre Tools
#6153 2
ZH07 G81 for Pre Tools
#6154 2
ZH08 G81 for Pre Tools
#6155 5
ZH07 G85 for Pre Tools
#6156 3
ZH08 G81 for Pre Tool
#6157 7
ZH08 G86 for Pre Tools
#6158 to
not used
- #6176
not used
...
#6199 99998
Display of ’Black Mark’
#6200 99999
Display asterix ( * )
•
Attention
After all datas are entered and verified, the
’SETTING (HANDY)’ parameter
PARAMETER WRITE = 0 ’DISABLE’
must be reset to ’0’ .
GEF # FL / escap-02-012000
Default File List GFKE-0041A-EN