6. STATUS DISPLAY BY SELF–DIAGNOSTIC DISPLAY
119
6.1 Displaying CNC Internal State
6.1.1 Procedure for displaying diagnostic screen
Display the CNC internal state as below:
Change by page change key
Input a diagnostic data
No. to be displayed.
[NO.SRH]
SYSTEM
[DGNOS]
6.1.2 Display of status in which command is not apparently
executed (No. 000 – 015)
No. Display Internal status when 1 is displayed
000 WATING FOR FIN
SIGNAL
M, S, T function is being executed
001 MOTION Move command in automatic operation is being
executed
002 DWELL Dwell is being executed
003 IN–POSITION
CHECK
In-position check is being performed
004 FEEDRATE OVER-
RIDE 0%
Override 0%
005 INTERLOCK/
START–LOCK
Interlock startlock is on.
006 SPINDLE SPEED
ARRIVAL CHECK
Waiting for spindle speed arrival signal to turn
on
010 PUNCHING Data is being output via reader puncher inter-
face
011 READING Data is being input via reader puncher interface
012 WAITING FOR
(UN)CLAMP
Waiting for index table clamp/unclamp before B
axis index table indexing start/after B axis index
table indexing end to complete
013 JOG FEEDRATE
OVERRIDE 0%
Jog override 0%
014 WAITING FOR RE-
SET, ESP, RRW
OFF
One of the emergency stop, external reset, re-
set & rewind or MDI panel reset key is on.
015 EXTERNAL PRO-
GRAM NUMBER
SEARCH
External program number search is active.
016 BACKGROUND
ACTIVE
Background is being used.