3
1
4
5
6
7
8
9
10
2
228
7) Parameters of Data server
Number
Contents Remarks
0900 Data server function
#0 DSV : The data server function is enabled (0)/
disabled (1)
#1 ONS : When the O number of the data server file
name and the O number in an NC program do
not match: file name (0)/NC program (1)
0911 Altemate MDI character
0912 Character not provided in MDI keys
8) Parameters of Power motion manager
Number
Contents Remarks
0960 Power motion manager
#0 SLV : When the power motion manager is selected,
the screen displays: one slave (0)/divided into
four (1)
#1 MD1 : These parameters set a slave parameter
input/output destination.
#2 MD2 : These parameters set a slave parameter
input/output destination.
In either case, slave parameters are output in
program format.
#3 PMN : The power motion manager function is:
enabled (0)/disabled (1)
0
MD2 MD1 Input/output destination
0 Part program storage
0
1 Memory card