8. PARAMETERS
315
28) Parameter for normal direction control
Number
Contents Remarks
5480 Number of the axis for controlling the normal
direction
M series
5481 Rotation speed of normal direction control axis M series
5482 Limit value that ignores the rotation insertion of
direction control axis
M series
5483 Limit value of movement that is executed at the
normal direction angle of a preceding block
M series
5484 M series
#0 SDC : In normal direction control if the amount of
C–axis movement is smaller than the value set
in parameter No.5485, a C–axis movement is
inserted (0)/not inserted before a block (1)
5485 Limit imposed on the insertion of a single block
for rotation about the normal direction control
axis
M series
29) Parameters for indexing index table
Number
Contents Remarks
5500 Parameters of indexing index table M series
#0 DDP : Decimal point input method is conventional
method (0)/electronic calculator method (1)
#1 REL : Relative position display is not rounded by 360
degrees (0)/rounded by 360 degrees (1)
#2 ABS : Displaying absolute coordinate value is not
rounded by 360 degrees (0)/rounded by 360
degrees (1)
#3 INC : Rotation in the G90 mode is not set to the
shorter way around the circumference (0)/set
to the shorter way around the circumference
(1)
#4 G90 : Indexing command is judged according to the
G90/G91 mode (0)/judged by an absolute
command (1)
#6 SIM : When the same block includes a command for
an index table indexing axis and a command
for another controlled axis, a P/S alarm
(No.136) is issued (0)/the commands are
executed (1)
#7 IDX : Index table indexing sequence is Type A (0)/
Type B (1)
PRM
3401#0=0
PRM
5500#3
PRM
5511=0
5511 Negative-direction rotation command M code M series
5512 Unit of index table indexing angle M series