9. ERROR CODE LIST
361
9.1 Alarms Displayed on NC Screen
9.1.1 Program errors (P/S alarm)
Number Message Contents
000 PLEASE TURN OFF
POWER
A parameter which requires the pow-
er off was input, turn off power.
001 TH PARITY ALARM TH alarm (A character with incorrect
parity was input).
Correct the program or tape.
002 TV PARITY ALARM TV alarm (The number of characters
in a block is odd). This alarm will be
generated only when the TV check is
effective.
003 TOO MANY DIGITS Data exceeding the maximum allow-
able number of digits was input. (Re-
fer to the item of max. programmable
dimensions.)
004 ADDRESS NOT FOUND A numeral or the sign “ – ” was input
without an address at the beginning
of a block. Modify the program .
005 NO DATA AFTER
ADDRESS
The address was not followed by the
appropriate data but was followed by
another address or EOB code.
Modify the program.
006 ILLEGAL USE OF
NEGATIVE SIGN
Sign “ – ” input error (Sign “ – ” was
input after an address with which it
cannot be used. Or two or more “ – ”
signs were input.)
Modify the program.
007 ILLEGAL USE OF DECIMAL
POINT
Decimal point “ . ” input error (A deci-
mal point was input after an address
with which it can not be used. Or two
decimal points were input.)
Modify the program.
009 ILLEGAL ADDRESS INPUT Unusable character was input in sig-
nificant area.
Modify the program.
010 IMPROPER G–CODE An unusable G code or G code corre-
sponding to the function not provided
is specified. Modify the program.
011 NO FEEDRATE
COMMANDED
Feedrate was not commanded to a
cutting feed or the feedrate was inad-
equate. Modify the program.
014
ILLEGAL LEAD COMMAND
(T series)
In variable lead threading, the lead
incremental and decremental out-
putted by address K exceed the
maximum command value or a com-
mand such that the lead becomes a
negative value is given.
Modify the program.
CAN NOT COMMAND G95
(M series)
A synchronous feed is specified
without the option for threading / syn-
chronous feed.
Modify the program.