8. PARAMETERS
229
9) Parameter for Axis control/Incremental system
Number
Contents Remarks
1001 Parameter relating to least input increment
#0 INM : Least command increment on linear axis is,
mm system (0)/inch system (1)
1002 Parameter relating to number of control axis
#0 JAX : Number of simultaneous controlled axis in
manual operation is, 1 axis (0)/3 axis (1)
#1 DLZ : Reference position return function without dog
is, disable (0)/enable (1)
#2 SFD : The reference position shift function is not used
(0)/used (1).
#3 AZR : For G28, specified when a reference position
has not yet been established, deceleration
dogs are used (0)/ALM 90 is issued (1).
#4 XIK : When an axis-by-axis interlock signal is applied
during nonlinear positioning, only the interlock
axis is stopped (0)/all axes are stopped (1).
#7 IDG : When the reference position is set without
dogs, automatic setting of the parameter (bit 0
of parameter No.1012) is: not performed (0)/
performed (1)
PRM
1005#1
M series
1004 Parameter relating to least input increment
#0 ISA :
#1 ISC :
#7 IPR : Least input increment of each axis is set to 1
time (0)/10 times (1) as of least command
increment
ISC ISA CODE Least input increment
0 0 IS–B 0.001 mm or 0.001 deg
0 1 IS–A 0.01 mm or 0.01 deg
1 0 IS–C 0.0001 mm or 0.0001 deg
M series