6. STATUS DISPLAY BY SELF–DIAGNOSTIC DISPLAY
137
(4) Selection of memory data
(a) Displaying the memory data screen
1 Press the
SYSTEM
function key. When the continuation menu
key
is pressed, the [W.DGNS] soft key appears. Then,
press the [W.DGNS] soft key to display the waveform
diagnosis (parameter) screen.
2 Press the [W.MEM] soft key.
3 The waveform diagnosis (memory data) screen appears. The
soft keys for operation selection are also displayed.
SELECT
[][][][][]
START
WAVE DIAGNOS. (MEMORY) O1234 N12345
CONDITION : 100 TRIGGER : G0123.4
DATA KINDS SAMPLING AXIS
POS ERROR X Y Z A B C U V
MOTION CMD XYZABCUV
CURRNT(%) X Y Z A B C U V
SPEED(RPM) NONE
TORQUE CMD NONE
HEAT SIMLT X Y Z A B C U V
SMPL TIME : 2.0 SEC
DATE : MEMORY
EDIT **** *** *** 08:20:52
4 The operation selection soft keys are as follows:
W.PRM
[][][][][]
W.GRPH W.MEM
Press
SELECT
[][][][][]
START
[][][][][]
PUNCH
Fig. 2 Soft Key Display
(b) Selecting memory data
1 Display the waveform diagnosis (memory data) screen.
2 Position the cursor and enter the required data. For sampling
axis selection, move the cursor to the desired data type, type
in desired axis names, then press the [SELECT] soft key or the
INPUT
key. The entered axis names appear in the sampling
axis field to the right of the selected data type field.
Example: XYZ + [SELECT] or
INPUT
3 When axis selection is completed, a sampling period for one
axis is displayed. Then, press the [START] soft key to start
data sampling.
NOTE1 Those items indicated by ***** cannot be set.
NOTE2 To change the selected axes, type in the desired
axes again, then press the [SELECT] soft key. If the
[SELECT] soft key is pressed without having typed
in any axes, no axes are selected.