3
1
4
5
6
7
8
9
10
2
336
Number RemarksContents
7050 Retrace function
#0 RV1 : When the tool moves backwards after feed
hold during forward feed with the retrace
function, the block is split at the feed hold
position and stored (0)/stored without being
split (1).
#5 MI0 : Set below value
#6 MI1 : Set below value
0
MI1 MI0 Fine acceleration/deceleration
0 Used
0
1 Not used
M series
M series
M series
7052 Simple high–precision contour control
#0 NMI : In simple high–precision contour control mode,
batch pass for each axis is enabled (0)/
disabled (1)
45) Parameters for manual handle feed / Interrupts / Tool axial direction
Number
Contents Remarks
7100 Parameter for manual pulse generator
#0 JHD : Manual pulse generator in JOG mode is invalid
(0)/valid (1)
#1 THD : Manual pulse generator in TEACH IN JOG
mode is invalid (0)/valid (1)
#2 IHD : The travel increment for manual handle
interrupt is output unit, and acceleration/
deceleration after interpolation is disabled
(0)/input unit, and acceleration/deceleration
after interpolation is enabled (1)
#3 HCL : The clearing of a handle interrupt travel
distance is invalid (0)/valid (1).
#4 HPF : If the specified manual handle feedrate
exceeds the rapid traverse rate, handle pulses
exceeding the rapid traverse rate are ignored
(0)/are not ignored such that the tool is moved
then stopped (1).
7102 Rotation direction <Axis>
#0 HNG : Axis movement direction for rotation direction
of manual pulse generator is same in direction
(0) / reverse in direction (1)
T series