3
1
4
5
6
7
8
9
10
2
384
Number ContentsMessage
5060 ILLEGAL PARAMETER IN
G02.3/G03.3
(M series)
Parameter setting is illegal.
No. 5641 (setting of the linear axis) is
not specified.
No. 5641 specifies an axis other than
a linear axis.
No. 5642 (setting of the rotation axis)
is not specified.
No. 5642 specifies an axis other than
a rotation axis.
The CNC cannot control the linear or
rotation axis (the value of No. 1010 is
exceeded).
5061 ILLEGAL FORMAT IN
G02.3/G03.3
(M series)
The command for exponential inter-
polation (G02.3/G03.3) contains a
format error.
Address I, J, or K is not specified.
Addresses I, J, and K are 0.
5062 ILLEGAL COMMAND IN
G02.3/G03.3
(M series)
The command for exponential inter-
polation (G02.3/G03.3) contains an
illegal value.
The specified value is not suitable for
exponential interpolation (for exam-
ple, a negative value is subject to ln).
5063 IS NOT PRESET AFTER
REF.
(M series)
The position counter was not preset
before the start of workpiece thick-
ness measurement. This alarm is is-
sued in the following cases:
(1) An attempt has been made to
start measurement without first
establishing the origin.
(2) An attempt has been made to
start measurement without first
presetting the position counter
after manual return to the origin.
5064 DIFFERRENT AXIS UNIT
(IS–B, IS–C)
(M series)
Circular interpolation has been spe-
cified on a plane consisting of axes
having different increment systems.
5065 DIFFERENT AXIS UNIT
(PMC AXIS)
(M series)
Axes having different increment sys-
tems have been specified in the
same DI/DO group for PMC axis con-
trol. Modify the setting of parameter
No. 8010.
5066 RESTART ILLEGAL
SEQUENCE NUMBER
(M series)
Sequence number 7xxx has been
read during search for the next se-
quence number at program restart
for the return/restart function.
5068 G31 P90 FORMAT ERROR
(M series)
No movement axis or more than one
movement axis has been specified.
5069 WHL–C ; ILLEGAL P–DATA Erroneous P data has been specified
for center selection during grinding
wheel wear compensation.
5073 NO DECIMAL POINT No decimal point has been specified
for an address requiring a decimal
point.
5074 ADDRESS DUPLICATION
ERROR
The same address has been speci-
fied two or more times in a single
block. Alternatively, two or more G
codes in the same group have been
specified in a single block.