8. PARAMETERS
247
Number RemarksContents
1922 Controlled axis number for slave 3 (dedicated
to the FSSB setting screen)
1923 Controlled axis number for slave 4 (dedicated
to the FSSB setting screen)
1924 Controlled axis number for slave 5 (dedicated
to the FSSB setting screen)
1925 Controlled axis number for slave 6 (dedicated
to the FSSB setting screen)
1926 Controlled axis number for slave 7 (dedicated
to the FSSB setting screen)
1927 Controlled axis number for slave 8 (dedicated
to the FSSB setting screen)
1928 Controlled axis number for slave 9 (dedicated
to the FSSB setting screen)
1929 Controlled axis number for slave 10 (dedicated
to the FSSB setting screen)
1931 Connector number for the first pulse module
(dedicated to the FSSB setting screen)
<Axis>
1932 Connector number for the second pulse module
(dedicated to the FSSB setting screen)
<Axis>
1933 Cs contour control axis (dedicated to the FSSB
setting screen)
<Axis>
1934 Master and slave axis numbers subject to
tandem control (dedicated to the FSSB setting
screen)
<Axis>
1936 Connector number of the first pulse module <Axis>
1937 Connector number of the second pulse module <Axis>
2000 Parameter for servo <Axis>
#0 PLC0 : 0.1 mm control is, not performed (0)/
performed (1)
#1 DGPR : When the power is turned on, the digital
servo parameter specific to the motor is set
(0)/not set (1).
#3 PRMC : Automatic calculation of parameter values
according to the number of PC pulses is not
performed (0)/performed (1)
#4 PGEx : Position gain range is not expanded (0)/
expanded by 8 times (1)
PRM2023,
2024, 1836