6. STATUS DISPLAY BY SELF–DIAGNOSTIC DISPLAY
147
6.5.1 I/O signal list
f : Available
F : Available only with
2–path control
– : Unavailable
Symbol Signal name Address
T
series
M
series
*+ED1 to *+ED8 External deceleration signal G118 f f
*+L1 to *+L8 Overtravel signal G114 f f
*-ED1 to *-ED8 External deceleration signal G120 f f
*-L1 to *-L8 Overtravel signal G116 f f
*ABSM Manual absolute signal G006#2 f f
*AFV0 to *AFV7 2nd feedrate override
signal
G013 f f
*BECLP B–axis clamp completion
signal
G038#7 – f
*BEUCP B–axis unclamp completion
signal
G038#6 – f
*CHLD Chopping hold signal G051#7 – f
*CHP8 to
*CHP0
Chopping feedrate override
signals
G051#0 to
#3
– f
*CRTOF Automatic erase CRT
screen display cancel
signal
G062#1 f f
*DEC1 to
*DEC8
Deceleration signal for
reference position return
X009 f f
*EAXSL Control axis selection
status signal
(PMC axis control)
F129#7 f f
*ESP
p
X008#4 f f
*ESP
G008#4 f f
*ESPA
G071#1 f f
*ESPB
Emergency stop signal
serial spindle
G075#1 f f
*ESPC
G205#1 f f
*FLWU Follow–up signal G007#5 f f
*FV0 to *FV7 Feedrate override signal G012 f f
*FV0E to *FV7E Feedrate override signal
(PMC axis control)
G151 f f
*FV0O to
*FV7O
Software operator’s panel
signal (*FV0 to *FV7)
F078 f f
*HROV0 to
*HROV6
1% step rapid traverse
override signal
G096#0 to
#6
f f
*IT Interlock signal G008#0 f f
*IT1 to *IT8 Interlock signal for each
axis
G130 f f
*JV0 to *JV15 Manual feedrate override
signal
G010,
G011
f f
*JV0O to
*JV15O
Software operator’s panel
signal(*JV0 to *JV15)
F079,
F080
f f