8. PARAMETERS
275
Number RemarksContents
3705 Parameter for gear shift of spindle
#0 ESF : The SF signal output condition is such that S
codes and SF are output with all S commands
(0)/not output when constant surface speed
control is used or the spindle speed is clamped
(1).
#1 GST : The SOR signal is used for spindle orientation
(0)/gear shift (1)
#2 SGB : The gear switching method is method A (0)/
method B (1)
#3 SGT : The gear switching method during G84 and
G74 is method A (0)/method B (1)
#4 EVS : With an S command, S codes and SF are not
output (0)/output (1).
#5 NSF : When an S code command is issued in
constant surface-speed control, SF is output
(0)/not output (1)
#6 SFA : The SF signal is output when gears are
switched (0)/irrespective of whether gears are
switched (1)
PRM
3705#5
M series
PRM3751,
3752
M series
PRM3741,
3743
M series
PRM3761,
3762
T series
M series
M series
3706 Parameter for the voltage polarity of spindle
#0 PG1 : The gear ratio of spindle to position coder
(1,2,4,8)
#1 PG2 : The gear ratio of spindle to position coder
(1,2,4,8)
#3 PCS : When multi-spindle control is used, feedback
signal selection, independent of the position
coder selection signal of the other tool post, is
disabled (0)/enabled (1).
#4 GTT : Spindle gear selection is based on M type (0)/
T type (1).
#5 ORM : The voltage polarity during spindle orientation
is positive (0)/negative (1)
#6 CWM : The voltage polarity when the spindle speed
voltage is output
#7 TCW : The voltage polarity when the spindle speed
voltage is output
1
2
4
8
PG2
0
0
1
1
0
0
1
1
TCW CWM Volt. polarity
0
1
0
1
M03, M04 = +
M03, M04 = –
M03 = +, M04 = –
M03 = –, M04 = +
PG1
0
1
0
1
T series
(2-path
control)
SLPCA
signal
SLPCB
signal
M series
PRM
3705#0