B-63322EN-1/01 10. PARAMETER
-61-
10.2
EXCLUSIVE PARAMETER FOR REMOTE BUFFER
#7 #6 #5 #4 #3 #2 #1 #0
5000 0 CDC ETX TCC ECH 422
[Input type] Parameter input
[Data type] Bit
NOTE
When this parameter is specified, the power must be
turned off and then on again for the parameter settings to
take effect.
#0 422 : Interface between the host and remote buffer
0 : RS-232-C
1 : RS-422
The system determines whether the remote buffer board
is provided with an RS-232-C or RS-422 interface, and
automatically sets the appropriate value.
#1 ECH : The response of the SAT at the switching between
remote operation and DNC operation is (for the protocol
A only):
0 : Always transmit 0 to SAT data part (Byte position 1)
1 : Echo back SET data part (Byte position 1) to SAT
data part (Byte position 1)
#2 TCC : Communication code
Communication code for protocol A
0 : ASCII
1 : ISO
Communication code for protocol B/expansion protocol
B (DC1, DC2, DC3, DC4, SYN, NAK)
0 : ISO
1 : ASCII
#3 ETX : For protocol A, the message end code is:
0 : CR code of ASCII/ISO
1 : ETX code of ASCII/ISO
(ASCII or ISO is selected by using the parameter
TCC.)
For protocol B or expansion protocol B, the remote
buffer:
0 : Does not post notification of CNC reset or an alarm
to the host computer.
1 : Transmits the SYN code for CNC reset, or the NAK
code for a CNC alarm.