B-63322EN-1/01 10. PARAMETER
-67-
10.3
PARAMETERS RELATED TO BINARY INPUT OPERATION
2010 Delay time of strobe signals MF, SF, TF, and BF
[Input section] Parameter input
[Data type] Integer type
[Unit of data] msec
[Valid data range] 0 to 32767
Set the time from the point an M, S, T, or B code is sent until the
strobe signal MF, SF, TF, or BF signal is sent.
2012 Output time of strobe signals MF, SF, TF, and BF
[Input section] Parameter input
[Data type] Integer type
[Unit of data] msec
[Valid data range] 0 to 32767
Set the time from the point the strobe signal MF, SF, TF, or BF is sent
until it is turned off.
2034 Type of auxiliary function used in binary input operation mode (remote buffer)
[Input section] Parameter input
[Data type] Integer type
[Valid data range] 0 to 3
Set the type of auxiliary function used in binary input operation mode.
0: Second auxiliary function
1: Miscellaneous function
2: S function
3. T function
M, S, T, or B code
MF, SF, TF, or BF signal
Delay time
M, S, T, or B code
MF, SF, TF, or BF signal
Delay time
Sending time