12. MAINTENANCE B-63322EN-1/01
-76-
12.3
DETERMINING THE LOGICAL SLOT NUMBER OF THE
REMOTE BUFFER BOARD
12.3.1
Determining the Logical Slot Number on the Screen
Displayed at the Time a System Alarm Occurs
Display hardware information 1 (display of F-BUS slot information),
shown below, using the page keys.
FANUC Series 15I F001A
SYS_ALM 300 SYSTEM ALARM (F-BUS SLOT (1))
OTHER-CPU
ERROR OCCURRED AT 1999/03/12 12:34:56
HARDWARE INFORMATION 1
F-BUS SLOT CONFIGURATION
6/27 MODULE NAME M ID SLOT IO DATA
+---------+-----------------------------+----------+---------------------------------------+
00:00 MOTHER BOARD 1234 0000 0000 0000 0000 0000
02:09 REMOTE BUFFER 10E1 0000 0000 0000 0000 0000
PAGE UP OR DOWN (PAGE 6/ 8)
On the screen, the second half of the number identified by the SLOT
column and the row containing REMOTE BUFFER (shown in the
MODULE NAME column) is the logical slot number. In the
example, the logical slot number of the remote buffer is 09.