B-63322EN-1/01 10. PARAMETER
-69-
TM2 TM1 TM0 Unit time
1001 msec
0012 msec
0104 msec
0008 msec
0 1 1 16 msec
7635 Number of axes in a single block that can accept commands (remote buffer)
[Input section] Parameter input
[Data type] Integer type
[Valid data range] 0 to number of controlled axes
Set the number of axes in a single block that can accept commands
when using binary input operation mode. Do not change this
parameter during operation.
NOTE
The axes that can accept commands from the remote
buffer are the first n axes in the controlled axis list, where
n is the number of axes specified for this parameter.
For example, when this parameter is 3, the fourth and
any subsequent axes in the controlled axis list cannot
accept commands.
#7 #6 #5 #4 #3 #2 #1 #0
7713 G5H
[Input section] Parameter input
[Data type] Bit type
#3 G5H In binary input operation mode, acceleration/deceleration
before look-ahead interpolation or fine HPCC is:
0: Enabled.
1: Disabled.
Only when the unit time is 1 msec (2 msec for a system
with 11 or more controlled axes),
acceleration/deceleration before look-ahead interpolation
or fine HPCC can be disabled in binary input operation
mode by using this parameter.
Note that to do this, acceleration/deceleration before
look-ahead interpolation or fine HPCC must be enabled.
In operation with the unit time shorter than 8 msec,
acceleration/deceleration before look-ahead interpolation