10. PARAMETER B-63322EN-1/01
-68-
#7 #6 #5 #4 #3 #2 #1 #0
7609 RAX RDS
[Input section] Parameter input
[Data type] Bit type
#2 RDS The data format for the travel distance along an axis in
remote buffer binary input operation mode is:
0: Special format
1: General format
#3 RAX In remote buffer binary input operation mode, auxiliary
functions are:
0: Not used.
1: Used.
#7 #6 #5 #4 #3 #2 #1 #0
2007 G5S
[Input section] Parameter input
[Data type] Bit type
#3 G5S In binary input operation mode, the single-block stop is:
0: Disabled.
1: Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
7618 TM2 TM1 TM0
[Input section] Parameter input
[Data type] Bit type
NOTE
When this parameter is specified, the power must be
turned off and then on again for the parameter settings to
take effect.
#0 TM0
#1 TM1 Travel distance per unit time along each axis
#2 TM2 In the format for remote buffer binary input operation
data, the travel distances per unit time along the
individual axes are arranged sequentially. Set the unit
time in msec.