B-63322EN-1/01 10. PARAMETER
-65-
NOTE
In the case when the protocol A/expansion protocol A
were selected, if the following parameters are modified,
they become valid after the power is turned off and then
on.
No. 5070, 5072, 5073
5081 RS-232-C Specification of I/O device (Remote buffer)
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 to 8
Set the specification number of the RS-232-C I/O device of the
remote buffer.
The specification numbers and their corresponding reader/punch
device specifications are as follows.
Specification
No.
Reader/punch device specification
1
Uses the control codes (DC1-DC4). Outputs feed by
punching. Tape reader.
2
Does not use the control codes (DC1-DC4). Outputs feed
by punching.
3
Uses the control codes (DC1-DC4). Does not outputs feed
by punching.
4
Does not use the control codes (DC1-DC4). Does not
outputs feed by punching.
7 FANUC CASSETTE (Bubble cassette)
8
FLOPPY CASSETTE, PROGRAM FILE Mate
Handy File (remote mode)
5082 RS-232-C Number of stop bits (Remote buffer)
[Input type] Setting input
[Data type] Integer
[Valid data range] 1 to 2
Set the number of stop bits of the RS-232-C device of the remote
buffer.
NOTE
When this stop bit is set to 1, the parity bit is also
provided.
5083 RS-232-C BAUD rate (Remote buffer)
[Input type] Setting input
[Data type] Integer
[Valid data range] 1 to 12