B-63322EN/03 NC FUNCTIONS 6.REFERENCE POSITION
- 87 -
6.5 2ND, 3RD AND 4TH REFERENCE POSITION RETURN
(G30)
With the G30 command, the commanded axis is positioned to the 2nd,
3rd, or the 4th reference position, via the commanded point. 2nd, 3rd,
or 4th reference position return end signal is output when positioning
ends. Set the 2nd, 3rd, and 4th reference position position as
parameters.
This function is available after power is turned on and reference
position return is performed.
G29 can be used to return from the 2nd, 3rd, and 4th reference point
(same as reference position return, G28) .
This function can be used once reference position return has been
performed after power-on.
Format
G30 P2 IP_ ; Second reference position (P2 is optional.)
G30 P3 IP_ ; Third reference position
G30 P4 IP_ ; Fourth reference position
IP : Command intermediate point