B-63322EN/03 NC FUNCTIONS 5.FEED FUNCTION
- 69 -
5.1 RAPID TRAVERSE
Positioning of each axis is done in rapid motion by the positioning
command (G00).
There is no need to program rapid traverse rate, because the rates are set
in the parameter (per axis)
Least command increment Rapid traverse rate range
0.001mm,deg 30 to 240000mm/min,deg/min
0.0001mm,deg 30 to 100000mm/min,deg/min
0.0001inch 3.0 to 24000.0inch/min
0.00001inch 3.0 to 10000.0inch/min
(When input unit is same machine unit,)
NOTE
The above feed rates are limits according to the NC’s
interpolation capacity when the high-resolution
detection interface is equipped. When the whole
system is considered, there are also limits according
to the servo system.