B-63322EN/03 NC FUNCTIONS 25.DISPLAY AND SETTING
- 347 -
25.30 FINE TORQUE SENSING
Disturbance load torque data detected by the servo motor or spindle
motor is stored in the internal memory of the CNC. Stored torque data
can be manipulated as described below.
1. Stored torque data can be displayed as a graph on the torque graph
screen.
2. On the torque graph screen, the detection level of the abnormal load
detection alarm can be set. (The abnormal load detection function
is another option.)
3. Stored torque data can be saved as sample data, and can be displayed
later as a graph together with new stored data for comparison.
4. Stored torque data can be saved in a memory card.
NOTE
1 This function cannot be used with an analog spindle.
2 When the display of the CNC is monochrome, and
has no graphic display capability, the torque graph
screen and torque parameter screen are not
displayed.