3 1999.7.05 Y.Wakinotani 15i is added T.Ohtsuki
2 1999.3.09 N.Hatanaka Overall revision T.Kurokawa
0221 Keyword 1 for remote diagnosis
0222 Keyword 2 for remote diagnosis
0223 Keyword 3 for remote diagnosis
[Valid data range] 1 - 99999999
These parameters set the keywords for passwords used with the remote diagnosis
function.
Keyword 1: Keyword for password 1 (parameter No.211)
Keyword 2: Keyword for password 2 (parameter No.212)
Keyword 3: Keyword for password 3 (parameter No.213)
When a value other than 0 is specified as a password (parameter No.211 to 213),
the password cannot be modified until the same value is set in the corresponding
keyword parameter.
NOTE
1 Upon power-up, the keyword parameters are set to 0.
2 The parameter screen does not display any set keyword value,