8. DATA INPUT/OUTPUT
B–63604EN/01
OPERATION
528
Offset data can be input and output using the ALL IO screen.
Inputting offset data
1 Press soft key [OFFSET] on the ALL IO screen, described in Section
III–8.10.1.
2 Select EDIT mode.
3 Press soft key [(OPRT)]. The screen and soft keys change as shown
below.
READ/PUNCH (OFFSET) O1234 N12345
MDI
*
* * * * * * * * * * * *
12:34:56
READ PUNCH
I/O CHANNEL 3 TV CHECK OFF
DEVICE NUM. 0 PUNCH CODE ISO
BAUDRATE 4800 INPUT CODE ASCII
STOP BIT 2 FEED OUTPUT FEED
NULL INPUT (EIA) NO EOB OUTPUT (ISO) CR
TV CHECK (NOTES) ON BAUDRATE CLK. INNER
CD CHECK (232C) OFF RESET/ALARM ON
PARITY BIT OFF COM CODE ASCII
END CODE EXT COM PROTCOL A
INTERFACE RS422 SAT COMMAND HOST
(0:EIA 1:ISO)>1_
4 Press soft key [READ], then [EXEC].
The offset data is read, and the “INPUT” indicator blinks at the
lower–right corner of the screen.
Upon the completion of input, the “INPUT” indicator is cleared from
the screen.
To cancel input, press soft key [CAN].
8.10.4
Inputting and
Outputting Offset Data
Procedure
EXECCAN