6.EXAMPLE OF LADDER DIAGRAM PMC PROGRAMMING B-63753EN/01
- 96 -
• About display character data of the first line.
LCD display character data of the following content is stored in
R0300-R0315 beforehand. See Fig.6.3(b) for the sequence.
Address
Character-
code
(decimal)
displayed
character
Transferring
by MOVN at
RUN time
Destination
address
R0300 91 [ → LCD_CHAR
R0301 74 J → LCD_CHAR+1
R0302 79 O → LCD_CHAR+2
R0303 71 G → LCD_CHAR+3
R0304 93 ] → LCD_CHAR+4
R0305 32 (Space) → LCD_CHAR+5
R0306 32 (Space) → LCD_CHAR+6
R0307 32 (Space) → LCD_CHAR+7
R0308 32 (Space) → LCD_CHAR+8
R0309 32 (Space) → LCD_CHAR+9
R0310 32 (Space) → LCD_CHAR+10
R0311 32 (Space) → LCD_CHAR+11
R0312 32 (Space) → LCD_CHAR+12
R0313 32 (Space) → LCD_CHAR+13
R0314 32 (Space) → LCD_CHAR+14
R0315 32 (Space) → LCD_CHAR+15
• About fixed display character of the 2nd line.
LCD display character data of the following content is stored in
R0316-R0331 beforehand. See Fig.6.3(b) for the sequence.
Address
Character-
code
(decimal)
displayed
character
Transferring
by MOVN at
RUN time
Destination
address
R0316 32 (Space) → LCD_CHAR
R0317 32 (Space) → LCD_CHAR+1
R0318 32 (Space) → LCD_CHAR+2
R0319 32 (Space) → LCD_CHAR+3
R0320 32 (Space) → LCD_CHAR+4
R0321 32 (Space) → LCD_CHAR+5
R0322 32 (Space) → LCD_CHAR+6
R0323 32 (Space) → LCD_CHAR+7
R0324 32 (Space) → LCD_CHAR+8
R0325 32 (Space) → LCD_CHAR+9
R0326 32 (Space) → LCD_CHAR+10
R0327 32 (Space) → LCD_CHAR+11
R0328 16 (variable) → LCD_CHAR+12
R0329 16 (variable) → LCD_CHAR+13
R0330 16 (variable) → LCD_CHAR+14
R0331 37 % → LCD_CHAR+15