B-63753EN/01 SPECIFICATION 3.MAINLY FUNCTIONS
- 5 -
3 MAINLY FUNCTIONS
• Input keys, operation ON/OFF switch and override switch on the
handy machine operator’s panel are read by PMC ladder
program.
• The position and messages with figures/alphabet/kana are
displayed on the LCD by PMC ladder program.
• The LEDs near the input keys are turned on/off by PMC ladder
program.
• The operation with manual pulse generator is possible.
• There is an emergency stop button to open emergency stop line
in the system.
• There is a three positions enabling switch to open emergency
stop line in the system. While the enabling switch is available,
the emergency stop line is opened with releasing the switch or
gripping it tightly.
• The enabling switch is enabled in automatically by the situation
that the operator exposes himself to danger, example the
observation working in the protection cover of cutting part, and
the working in the fence for danger area. This switch is not used,
when the operator is in a safety situation.
• The additional circuit of the emergency stop button and the
enabling switch is provided for safety.
• The emergency stop button and the enabling switch on the handy
machine operator’s panel are parts of emergency stop circuit in
this system. CNC and servo amplifier must be connected the
emergency stop circuit.
• Detachable connection is possible by providing the connection
panel on the cabinet.