3.PREPARATIONS FOR USING PMC PROGRAMMING B-63753EN/01
- 62 -
3.1 ASSIGNMENT OF ADDRESS
Assignment of I/O Link address is needed for LADDER program
because the handy machine operator’s panel is connected to CNC by
I/O link. Handy machine operator's panel uses continuous 16 bytes for
X and continuous 32 bytes for Y on I/O Link. Please make the
number and the name of specified [Base no], [Slot no], and [assigned
name] strictly the same as the following. Though HMOP occupies 16
bytes of inputs, the occupied input point for this group is recognized
as 32 bytes as same as outputs.
NOTE
The occupied input/output point for Handy machine
operator’s panel is 32 bytes/32 bytes.
(1) Assignment of PMC X address
X
Address
Group
No.
Base No. Slot No.
Assigned
name
Occupied
address
X+0 n 0 0 ## 4bytes
X+4 n 0 1 #2 2bytes
X+6 n 0 2 #2 2bytes
X+8 n 0 3 #2 2bytes
X+10 n 0 4 #2 2bytes
X+12 n 0 5 #2 2bytes
X+14 n 0 6 #2 2bytes
Total bytes 16bytes
(Note) 0 ≤ n ≤ 15
(2) Assignment of PMC Y address
Y
Address
Group
No.
Base No. Slot No.
Assigned
name
Occupied
address
Y+0 n 0 7 #2 2bytes
Y+2 n 0 8 #2 2bytes
Y+4 n 0 9 #2 2bytes
Y+6 n 0 10 #2 2bytes
Y+8 n 0 11 #2 2bytes
Y+10 n 0 12 #2 2bytes
Y+12 n 0 13 #2 2bytes
Y+14 n 0 14 #2 2bytes
Y+16 n 0 15 #2 2bytes
Y+18 n 0 16 #2 2bytes
Y+20 n 0 17 #2 2bytes
Y+22 n 0 18 #2 2bytes
Y+24 n 0 19 #2 2bytes
Y+26 n 0 20 #2 2bytes
Y+28 n 0 21 #2 2bytes
Y+30 n 0 22 #2 2bytes
Total bytes 32bytes
(Note) 0 ≤ n ≤ 15