B-63753EN/01 PMC PROGRAMMING4.OUTLINE OF HANDY MACHINE OPERATOR'S PANEL FUNCTIONS
- 73 -
4.4.2 LCD Display Control 2
These are output signals to HMOP for using LCD display control.
Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Y+4
(Reserved) (Reserved) (Reserved) (Reserved) (Reserved) (Reserved) REQDSP SELLN
Bit 0: Selecting the line to display characters on LCD
Bit 0
SELLN
Description
0 1st(upper) line is selected.
1 2nd(lower) line is selected.
Bit 1: Request to display characters on LCD
Bit 1
REQDSP
Description
0 Reset request.
1 Set request.
4.4.3 Displayed Character of Selected Line
Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Y+5
CDATA1 : 1st (left)
character
Y+6
CDATA2 : 2nd
character
Y+7
CDATA3 : 3rd
character
Y+8
CDATA4 : 4th character
Y+9
CDATA5 : 5th character
Y+10
CDATA6 : 6th character
Y+11
CDATA7 : 7th character
Y+12
CDATA8 : 8th character
Y+13
CDATA9 : 9th character
Y+14
CDATA10 : 10th character
Y+15
CDATA11 : 11th character
Y+16
CDATA12 : 12th character
Y+17
CDATA13 : 13th character
Y+18
CDATA14 : 14th character
Y+19
CDATA15 : 15th character
Y+20
CDATA16 : 16th (right) character
• The leftmost digit on the LCD indicates the first character, the
next leftmost digit the second, ---, and rightmost digit the 16th.
LCD one line
1st line 1st char. 2nd char. to 15th char. 16th char.
2nd line 1st char. 2nd char. to 15th char. 16th char.
• See Subsection “4.4.8 LCD character-code table" for the
character-code which can be set.