2.SPECIFICATION SPECIFICATION B-63753EN/01
- 4 -
2 SPECIFICATION
Manual pulse generator
Including
Display
LCD 16 characters × 2 lines
Input key
20 (with LED)
LED
User programmable LED × 2, system LED × 2
Key sheet
FANUC standard key sheet is provided.
Customization of key sheet is possible with user’s order.
And it can be customized simply with putting their seals.
Operation ON/OFF switch
Including
Rotary switch
16 positions (for override)
Emergency stop button
2 contacts
Enabling switch
2 contacts , 3 positions
Interface
FANUC I/O Link via interface unit
Additional circuit is provided to emergency stop system.
Cable length
Between handy machine operator’s panel and interface unit is up to 50m.
Input power
24VDC±10% 0.4A (include a moment and ripple)
<Sum of Handy machine operator’s panel and interface unit>
Handy machine operator’s panel Interface unit
External dimensions
130 (W)×255 (H) ×104 (D) mm 32 (W) ×122 (H) ×113 (D) mm
Weight
About 700g
(not include the connection cable)
About 200g
Protect
IP54 -
Specification number
Unit : A02B-0259-C221#A (with FANUC
standard key sheet A)
Transparent key sheet :
A02B-0259-K130
A02B-0259-C220
NOTE
1 Connecting cables are not included in the handy machine operator’s panel.
2 Power supply unit and cables must be prepared by user.
3 When detachable connection, connector panel must be prepared by user.
4 In view of CE standard, there is a possibility that detachable connection by installing
the connection panel in the cabinet is not permitted. (This is to bypass the
emergency stop circuit.) Please confirm it to CE competent body. When detachable
connection is not permitted, please use handy machine operator’s panel by keeping
always.