B-64004EN/02 6.PARAMETERS
- 95 -
Position switch sometimes turns on and off repeatedly near the
boundary of position switch area by very small vibration of a servo
motor. According to this problem, position switch is inconvenient to
use. So “hysteresis” described below is applied.
Maximum limit of
position switch
Minimum limit of
position switch
Width of hysteresis Width of hysteresis
ctivated area of position switch
Fig.6.5(a) Measuring area of position switch in case state of switch is “0”
Minimum limit of
position switch
Maximum limit of
position switch
ctivated area of position switch
Fig.6.5(b) Measuring area of position switch in case state of switch is “1”
The position switch is checked at every sampling period. When the
minimum and maximum limit of position switch are given like above
figure, activated area is checked by the area shown in the figure 6.5(a)
considering hysteresis if the state of position switch measured at last
time is “0”. And activated area is checked by the area shown in the
figure 6.5(b) not considering hysteresis if the state of position switch
measured at last time is “1”. According to this, it is possible to
suppress frequent changing of position switch.
13821 Safety limit speed 1 in position control for each axis
13822 Safety limit speed 2 in position control for each axis
13823 Safety limit speed 3 in position control for each axis
13824 Safety limit speed 4 in position control for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis