No. Message SP
indication
Faulty location and remedy Description
SP9016 SSPA:16 RAM
ERROR
16 Replace the SPM unit. An error occurred in a spindle RAM test.
Replace spindle amplifier module.
SP9069 SAFETY SPEED
OVER
69 1 Check the safety speed
parameter (parameter No.4372/
No.4438/No.4440 /No.4442).
2 Perform operation at a speed
not exceeding the safety speed.
The spindle detected that the speed of the
spindle motor exceeded the safety speed
(parameter No. 4372/No.4438/No.4440
/No.4442) during safety monitoring (the
safety check request signal (*VLDPs) is 0).
SP9070 ILLEGAL AXIS
DATA
70 1 Check the spindle amplifier
connection state and spindle
amplifier hardware setting.
2 If this alarm is issued because
the spindle amplifier
configuration is changed, correct
the setting on the spindle
amplifier side.
The spindle detected a mismatch between
the spindle amplifier connection state and
spindle amplifier hardware setting.
If this alarm is issued because the spindle
amplifier configuration is changed, correct
the setting on the spindle amplifier side.
SP9071 SAFETY PARAM
ERROR
71 Set the safety parameter again.
The following are spindle safety
parameters. (No.4372/No.4438
/No.4440/No.4442/No.4448)
The spindle detected a safety parameter
error.
SP9072 MISMATCH
RESULT OF
MOTOR SPEED
CHECK
72 Replace the SPM control
printed-circuit board.
The spindle detected a mismatch between
the CNC result of the motor speed check
and the spindle result of it.
SP9074 CPU TEST
ERROR
74 Replace the SPM control
printed-circuit board.
An error occurred in a spindle amplifier
CPU test.
75 Replace the SPM control
printed-circuit board.
An error occurred in a spindle ROM CRC
test.
SP9076 INEXECUTION OF
SAFETY
FUNCTIONS
76 Replace the SPM control
printed-circuit board.
Any safety function was not executed.
SP9077 MISSMATCH THE
RESULTS OF
AXIS NUMBER
CHECK
77 Replace the SPM control
printed-circuit board.
The spindle detected a mismatch between
the CNC result of the axis number check
and the spindle result of it.
SP9078 MISSMATCH THE
RESULTS OF
SAFETY
PARAMETER
78 Set the safety parameter again.
The following are spindle safety
parameters. (No.4372/No.4438
/No.4440/No.4442/No.4448)
The spindle CPU detected a mismatch
between the CNC result of the safety
parameters check and the spindle result of
it.
79 Replace the SPM control
printed-circuit board.
The safety functions at power-up for
spindle were not executed.
- Boot System Alarms
Message Description
CRC CHECK ERROR:NC BASIC. CRC error occurs in CNC BASIC ROM. Please install CNC BASIC ROM in flash
memory again.