B-64004EN/02 3.SAFETY FUNCTIONS
- 21 -
This section briefly describes the signals. For details, see Chapter
5, “OPERATION.” For specific connections, see the sample
system configuration in Chapter 10.
NOTE
1 Dual Check Safety PMC (DCS PMC)
2 First path PMC, Second path PMC, Third path
PMC
Please refer to “FANUC Series
30i/300i/300is-MODEL A PMC
PROGRAMMING MANUAL (B-63983EN)”
3 When I/O Link and PROFIBUS-DP are connected
to DCS PMC at the same time, the X/Y signals
cannot be allocated to PROFIBUS-DP.
4 Please activate “Broken wire detection” of the
slave, which connect with PROFIBUS network as
Safety-related I/O. As for detail, please refer to
“6.6. PROFIBUS-DP parameter settings”.
CAUTION
Ladder functional instruction MOVB, MOVD and
MOVW cannot be used with ladder for Dual Check
Safety PMC. Use MOVN instead of them.