1.OVERVIEW B-64004EN/02
- 6 -
PMC
CPU
Cross-check
Motor detector
Shut off power
Servo
Spindle
CPU
Door switch signal
Magnetic
contactor
CPU
CNCCNC
CPU
Shut off power
results
of data and
signal
Monitoring of servo motor and spindle motor movement
Data output from the detector built into each motor is transferred to
the CNC through the amplifier. The safety of this path is ensured by
using motors and amplifiers specified by FANUC.
Cross-monitoring using 2 CPUs
Two CPUs built into the CNC are used to cross-monitor the safety
function. Each CPU is periodically checked for errors. If one
system fails, the servo system and spindle can be stopped safely.
Power shutoff via two paths
If an error is detected, the power is shut off via two power shutoff
paths. The paths need to be tested for built-up failures within a
certain time.
Input signal safety
Safety-related input signals such as the protection door lock/unlock
signal are monitored doubly. If a mismatch between the two
occurrences of a signal is detected, the power to the motor drive
circuit is shut off. This cross-check is constantly made.
Output signal safety
A signal is output (via two paths) to the relay used to shut off the
power to the motor drive circuit. An error is detected by a MCC off
Test. For detection of built-up failures, a MCC off Test needs to be
conducted at certain intervals. This MCC off Test is not mandatory
when machining is performed with the protection door closed. (The
MCC off Test should be performed, before the protection door is open
after the certain intervals.)