B-64004EN/02 6.PARAMETERS
- 79 -
(C) Velocity and angular velocity parameters
Unit of data
Increment
system
Minimum
data unit
Valid data range
IS-A 0.01 0.0 to +999000.00
IS-B 0.001 0.0 to +999000.000
IS-C 0.0001 0.0 to +99999.9999
IS-D 0.00001 0.0 to +9999.99999
mm/min
degree/min
IS-E 0.000001 0.0 to +999.999999
IS-A 0.001 0.0 to +96000.000
IS-B 0.0001 0.0 to +9600.0000
IS-C 0.00001 0.0 to +4000.00000
IS-D 0.000001 0.0 to +400.000000
inch/min
IS-E 0.0000001 0.0 to +40.0000000
(D)Acceleration and angular acceleration parameters
Unit of data
Increment
system
Minimum
data unit
Valid data range
IS-A 0.01 0.00 to +999999.99
IS-B 0.001 0.000 to +999999.999
IS-C 0.0001 0.0000 to +99999.9999
IS-D 0.00001 0.00000 to +9999.99999
mm/sec
2
deg./sec
2
IS-E 0.000001 0.000000 to +999.999999
IS-A 0.001 0.000 to +99999.999
IS-B 0.0001 0.0000 to +99999.9999
IS-C 0.00001 0.00000 to +9999.99999
IS-D 0.000001 0.000000 to +999.999999
inch/sec
2
IS-E 0.0000001 0.0000000 to +99.9999999
Notes
(1) Values are rounded up or down to the nearest multiples of the
minimum data unit.
(2) A valid data range means data input limits, and may differ from
values representing actual performance.
(3) For information on the ranges of commands to the CNC, refer to
Appendix, "List of Command Ranges," in the "USER’S
MANUAL" (B-63944EN).
(4) The setting value of the parameter related with length and angle
depends on whether the attribute of the axis is diameter
specification or radius specification. In case safety function, set
the parameter according to the attribute of the axis at power on.
Even if the attribute is changed after power on, changed value is
not used by each safety function. Each safety function refers to
the value that is specified at power on. .