B-64004EN/02 5.I/O SIGNALS
- 53 -
5.3 SIGNALS
Emergency Stop signal (input)
*ESP <PMC:X008#4, #0, #1><DCS PMC:X008#4, #0, #1> (for each machine group)
*ESP <PMC: Gn008#4> <DCS PMC: G(019+m)#4> (for each path)
This is Emergency Stop signal. The Emergency Stop signal must be
connected to the Emergency Stop input of the amplifier.
[Classification] Input signal (Dual signal)
[Function] Stops machine movement immediately in an emergency.
0: Emergency stop state
1: Normal state
[Operation] When Emergency Stop signal (*ESP) is set to 0, the CNC is reset, and
the system enters emergency stop state. A machine tool builder must
output a signal to shut off directly the MCC when “MCC Off signal”
(*MCF) is set to “0”.
In emergency stop state, a machine tool builder must check “MCC
Contact State signal” (*SMC). If *SMC signal is “0” (MCC is on), a
machine tool builder must not release the guard lock signal of
protective door.
In general, Emergency Stop signal (*ESP) is specified by the
pushbutton switch B contact. When an emergency stop occurs, the
servo ready signal SA is set to 0.
If the input of the Emergency Stop signal is detected, the CNC
automatically specifies a command to zero the speed of a servo motor
and reduces the speed to zero (controlled stop). (See below note) After
the servo motor slows down and stops, the power is turned off, and the
servo motor is brought into the dynamic brake stop state.
The spindle motor is slowed down by the PMC command (see below
note) and the power is shut off.