7.START-UP B-64004EN/02
- 114 -
Step 6
Test for checking the safety function
Check test execution and report creation
Step 7
Parameter preservation
Save all parameters including the safety parameters. The
parameters are used to start up the series.
Step 8
Set a password.
A password is used to disable unauthorized persons from
modifying safety parameters. Before safety parameters of the
equipment for which a password (No. 3225) is set can be
modified, the password value must be set as the keyword (No.
3226). Only those persons authorized to conduct a check test
should know the password value.
7.2.2 Series start-up
The parameters for the safety monitoring function are transferred
together with other parameters to the CNC as in the case of normal
series start-up. Perform a safety function check test in addition to the
normal start-up procedure.
7.2.3 Troubleshooting
Alarms related to the safety function are output on the ALARM
screen.
Correct the cause of trouble according to the chapter describing alarms
and messages in this manual. When a component related to the
safety function is to be replaced, an authorized person must conduct a
safety function check test.