6.PARAMETERS B-64004EN/02
- 82 -
1838 Position deviation limit for each axis in moving state during safety check
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
Position deviation limit for each axis in moving state for safety check
of Dual Check Safety function is specified.
If position deviation of a moving axis exceeds position deviation limit
while Safety Check is carried out (Safety Monitoring Request
“*VLDVx” =0), a servo alarm (SV0475, SV1071) is generated and
axes are stopped immediately like emergency stop state.
In Dual Check Safety function, position deviation is always checked
by CNC and Servo. In case that Safety Check is carried out (Safety
Monitoring Request “*VLDVx” =0), the servo alarm
(SV0475,SV1071) is generated when each CPU finds out that the
deviation exceeds position deviation limit in moving state.
1839 Position deviation limit for each axis in stopped state during safety check
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
Set the positioning deviation limit in stopped state for each axis for
Dual Check Safety function.
If the positioning deviation exceeds the positioning deviation limit
during stopped state while Safety Check is carried out (Safety
Monitoring Request “*VLDVx” =0), a servo alarm (SV0474,
SV1072) is generated, and operation is stopped immediately (as in
emergency stop).
In Dual Check Safety function, position deviation is always checked
by CNC and Servo. In case that Safety Check is carried out (Safety
Monitoring Request “*VLDVx” =0), servo alarm (SV0474,SV1072)
is generated when each CPU finds out that the deviation exceeds
position deviation limit in stopped state.