1.16i/18i/21i-A/B, Power Mate i-D/H, AND 16/18-C OPERATION B-62924EN/04
- 16 -
(3) Pressing soft key [MASTER] displays Screen 1-2.
Screen 1-2
(4) The following parameters can be set by pressing the
corresponding soft keys on the screen 1-2:
<1> Bus parameters [BUS]
<2> Slave parameters [SLAVE]
<3> Operation mode [MODE]
Pressing soft key [INI.AL] has the same effect as performing
initialization by pressing soft key [INIT] on the bus parameter setting
screen, slave parameter setting screen, or address assignment screen.
For the initialized values on these screens, see the descriptions of the
relevant sections.
REFRESH TIME indicates the time required for updating DI/DO data
for the master function. For details, see Section 1.2.5, "Updating
DI/DO Data for the Master Function."