B-62924EN/04 OPERATION 1.16i/18i/21i-A/B, Power Mate i-D/H, AND 16/18-C
- 37 -
1.3 SLAVE FUNCTION SETTING
Addresses must be assigned on a DP-Slave before the slave function
can be used.
By address assignment, a PMC address is set, and the sizes of the
DI/DO areas used for the DI/DO signal transfer between the DP-
Master and DP-Slave are set. The method of setting each parameter is
described below.
NOTE
Before a DP-Slave manufactured by FANUC can be
used, data dependent on the FANUC DP-Slave must
be set in the slave parameters of the DP-Master. So,
when setting the slave parameters of the DP-Master,
see Section 1.4, "Setting the Slave Parameters for
Using a slave Station Manufactured by FANUC."
Procedure (CRT/MDI)
(1) Press function key <SYSTEM>. Then, press soft key [PMC] to
switch to the PMC screen.
(2) Pressing soft keys [PMCDGN], [IOCHK] , and [PROFI] in the
stated order displays Screen 1-9.
Screen 1-9