B-62924EN/04 OPERATION 3.Power Mate-D/H
- 89 -
3.2 SETTING THE SLAVE PARAMETERS FOR USING A SLAVE
STATION MANUFACTURED BY FANUC
Before the slave station manufactured by FANUC can be used, data
dependent on the FANUC slave station must be set in the slave
parameters of the master station.
Table 3-1 indicates the values to be set in the slave parameters. Note
that if valid values are not set in these parameters, communication
may not be performed normally. (For the meaning of each slave
parameter, refer to the manuals for the remote master station.)
Table 3-1 Settings of the Slave Parameters
Item Setting/description
00A0: CNC
00A1: Power Mate CNC
IDENT NO.
Identification number of a slave station using a PROFIBUS product manufactured by FANUC.
C0SLAVE FLAG
Slave specification bit flag.
0SLAVE TYPE
Manufacturer-specified slave type.
88STATION
STATUS
Bit flag where LOCK_REQ, UNLOCK_REQ, SYNC_REQ, FREEZE_REQ, and WD_REQ are
assigned to the bits starting from the higher bit (Bits 2, 1, and 0 are not used).
LOCK_REQ and WD_REQ only are set to ON.
ArbitraryWD FACT1, 2
Set an appropriate value according to a desired disconnection detection time.
ArbitraryMIN TSDR
Set an appropriate value according to the state of the network.
0GROUP IDENT
Set an identification group to be used when SYNC_REQ and FREEZE_REQ are used. With the
slave function of a FANUC CNC, the SYNC_REQ and FREEZE_REQ functions cannot be used.
So, specify 0.
Data size : 0
Data : None
USER PRM
DATA
User parameter data.
With the slave function of a FANUC CNC, this data is not used. So, specify 0.
Data size : 0
Data : None
USER PRM
DATA
User parameter data.
With the slave function of a FANUC CNC, this data is not used. So, specify 0.
Data size : 3
Data : C0, Number of output bytes - 1, Number of input bytes - 1
CONFIG DATA
Configuration data.
As the data size, specify 3.
As data, specify C0 in the first byte, followed by the number of output bytes - 1 and the number of
input bytes - 1.
For the input/output of 32-byte output data (256 points) and 16-byte input data (128 points), for
example, specify C0, 1F, 0F in the data field.
Data size : 0
Data : None
SLAVE USER
DATA
Slave user data.
With the slave function of a FANUC CNC, this data is not used. So, specify 0.
NOTE
All settings indicated in Table 3-1 are represented in hexadecimal.