TITLE: Additional explanation of
PROFIBUS-DP Master function
(I/O Module Assignment function)
B-62924EN/04-1
FANUC LTD.
02.10.7
DRAW.NO.
(5) After inputting module data, by pressing the return key [<], the display returns to
Screen 1-8. Please confirm that “MOD” indicates either of the following conditions;
(a) through (e).
[Explanation of MOD]
(a)” - - - ” : The module is not configured yet.
(This module is regarded as “MODULE LENGH = 0”)
(b)" I / - " : The module has the input interface only.
(c)" - / 0 " : The module has the output interface only.
(d)" I / 0 " : The module has the input and output interface.
(e)" - / - " : The module has neither input/output interface.
(This module is regarded as “MODULE LENGTH = 1 and
MODULE(HEX) = 00”)
(f)"OVR" : At one slave station, the total of DI/DO size is over 244 bytes.
(g)"ERR" : the module data is not correct.
(6)And then please move the cursor at the first slot of the slave, and press the soft key
[SIZ.AT]. The DI/DO size of every slot will be configured automatically according to
the contents of the module data.
CAUTION
DI/DO size of every slot should be configured by using the soft key
[SIZ.AT].
(7)Please configure DI/DO address of every slot.
(8)About every slave station, please repeat the operation (1)- (7).
(9)To do the above operation, the following keys will be convenient.
[PR.SLV], [NX.SLV] :
By pressing the soft keys [PRV.SLV] and [NXT.SLV], the slave number of a
DP-Slave to be set can be changed. To move to the screen of a desired slave number
directly, enter a slave number, then press the soft key [PRV.SLV] or [NXT.SLV].
[ ADD ] :
A new slot index can be added.
[ DELETE ] :
The selected slot index can be deleted.